Skip to content

Accudyno ACCU-30-0300

Brand Accudyno
Model ACCU-30-0300
Output Type Differential mode (signal ground and power supply ground are different)
Sensor Type Bosch LSU 4.9
Fuse 5A

Wideband controller with display. Can be connected to 12V battery or a 12V/5A power supply.

Typical installation is a fixed installation in the exhaust pipe, a few centimeters after the manifold junction. In dynamometers, it can be used with an adapter at the exhaust pipe outlet as explained here.

IMPORTANT

Read the manufacturer's instructions and follow the recommendations for position, mounting, and fuse.

Accudyno cable included

The ACCU-30-0300 controller ships with the Accudyno Gyra/Forza connection cable pre-terminated, with the Analog− to GND junction already resolved. No additional wiring is required for Gyra/Forza.

Connection to Accudyno

Connect the grounds together

Wideband controllers with differential analog output have a negative output different from the battery negative. For them to work properly with Accudyno, all grounds must be connected at a common point, as shown in the figure, since Accudyno has common mode input, not differential.

Loading SVG...
Wire/Color Function GO/PRO
Red Positive Power Supply (+) Battery(+)
Black Negative Power Supply (-) Battery(-)
White Analog Output (+) Accudyno IN+ (AFR Pin 3)
Brown Analog Output (-) Accudyno IN- (AFR Pin 2) and Battery(-)

Calibration

Voltage Lambda AFR (Gasoline)
0.5 V 0.58 8.50
4.5 V 1.23 18.00

Scaling formulas (see full manual):

  • AFR = (2.3750 × Volts) + 7.3125
  • Lambda = (0.1621 × Volts) + 0.4990